PSI Fluid Power
Home

(03) 9899 6444 phone

skip to the main content area of this pagePSI Supplies Pty Ltd trading as PSI Fluid Power
Fairchild Industrial Products

Fairchild 64A & 65A Service Regulator


Fairchild Industrial Products Company

The Fairchild 64A and Fairchild 65A Service Regulators are precision units used in instrumentation and general purpose applications. An Aspirator Tube compensates downstream pressure droop under flow conditions, and a large Control Diaphragm area provides increased sensitivity.

Features

  • The Fairchild 64A and Fairchild 65A Service Regulators are precision units used in instrumentation and general purpose applications.
  • An Aspirator Tube compensates downstream pressure droop under flow conditions.
  • A large Control Diaphragm area provides increased sensitivity.
  • A full Flow Gage Port provides convenient pressure gage mounting.
  • The Fairchild 65 Standard 5-Micron Filter prevents particles from entering the output airstream.
  • The Fairchild 65 Filter Dripwell contains a Petcock Valve to easily drain trapped liquids.

Operating Principles

When you adjust the Range Screw to a specific setpoint, the Range Spring exerts a downward force against the top of the Control Diaphragm. This downward force opens the Supply Valve. Output pressure flows through the Outlet Port and the Aspirator Tube to the Control Chamber where it creates an upward force on the bottom of the Control Diaphragm.

When the setpoint is reached, the force of the Range Spring that acts on the top of the Control Diaphragm balances with the force of output pressure that acts on the bottom of the Control Diaphragm and closes the Supply Valve.

When the output pressure increases above the set point, the Diaphragm Assembly moves upward to close the Supply Valve and open the Exhaust Valve. Output pressure flows through the Exhaust Valve and out of the Vent on the side of the unit until it reaches the setpoint. For more information, see cross sectional diagram.

Fairchild 64A Fairchild 65A Service Regulator

Specifications

Supply Pressure
300 psig, [21.0 BAR], (2100 kPa) Maximum
Flow Capacity (SCFM)
22 (37.4 m3/HR) @ 100 psig, [7 BAR], (700 kPa) supply and 20 psig, [1.5 BAR], (150 kPa) setpoint
Exhaust Capacity (SCFM)
1 (1.72 m3/HR) where d ownstream pressure is 5 psig, [.35 BAR], (35 kPa) above 20 psig, [1.5 BAR], (150 kPa) setpoint
Supply Pressure Effect
Less than 0.1 psig, [.007 BAR, (1.7 kPa) for 25 psig, [1.7 BAR], (170 kPa) change in supply pressure
Sensitivity
1” (2.50 cm) Water Column
Temperature Range
-40oF to + 180o F, (-40o C to + 82o C)
Materials of Construction
Body and Housing: Aluminum
Trim: Zinc Plated Steel, Brass
Elastomers: Nitrile on Dacron

PDFCatalogue Pages including ordering details

PDFFairchild 64A Installation, Operation and Maintenance Instructions

PDFFairchild 65A Installation, Operation and Maintenance Instructions

This website and its content is copyright of P.S.I. Supplies Pty Ltd - © 2010. All rights reserved. Copyright, Disclaimer, Terms & Conditions
P.S.I. Supplies Pty Ltd trading as PSI Fluid Power